Our Services

Data Center Management & Smart Energy Solutions (DCIM/BMS/EMS)

ThaiConnect delivers DCIM monitoring, BMS Battery Monitor, and Smart EMS Controller services for AI Hyperscale & Edge Data Centers — backed by 15+ years of experience and certified engineers across Thailand.

DCIMReal-time monitoring for AI Hyperscale & Edge Data Centers

Data Center Infrastructure Management (DCIM)

Comprehensive Data Center Infrastructure Management software for real-time monitoring and automated alerts via Web Dashboard. Control power (PUE), temperature, humidity, and UPS from anywhere. Scales from Edge DC to AI Hyperscale Data Centers.

Key Benefits

  • Reduce PUE (Power Usage Effectiveness) by up to 20%
  • Automated alerts via Email, LINE, and SMS before incidents occur
  • Real-time Web Dashboard accessible from any device
  • Supports SNMP, Modbus, BACnet, and all standard protocols
  • Automated Capacity Planning and Energy Trend reports
  • Easy installation with no system downtime required
Request a DCIM Quote

Technical Specifications

Protocols
SNMP v1/v2c/v3, Modbus TCP/RTU, BACnet
Node Count
ไม่จำกัด (License-based)
Alerts
Email, LINE Notify, SMS, SNMP Trap
Dashboard
Web-based, Mobile Responsive
Database
MySQL / PostgreSQL
Supported OS
Windows Server, Linux (Ubuntu/CentOS)
BMSReal-time UPS battery health monitoring for Data Centers

Online Battery Monitoring System (BMS)

Real-time online battery monitoring system measuring voltage, current, temperature, and State of Health (SOH) of every battery cell. Automatic alerts on abnormal readings extend battery life and protect your UPS systems in AI Data Centers.

Key Benefits

  • Extend battery life by 20–30% through proactive monitoring
  • Detect degraded batteries before emergency failures occur
  • Real-time measurement of voltage, current, and temperature per cell
  • Supports Lead Acid and Ni-Cad batteries — up to 256 cells
  • SOH (State of Health) and SOC (State of Charge) reporting
  • Reduce premature battery replacement costs significantly
Request a BMS Quote

Technical Specifications

Model
DFUN PBMS9000+61
Cell Count
สูงสุด 256 Cell ต่อ Unit
Accuracy
±0.1% (แรงดัน), ±0.5°C (อุณหภูมิ)
Communication
RS485 Modbus, Ethernet TCP/IP
Battery Types
Lead Acid, Ni-Cad
Standards
CE, RoHS, DIN Rail
EMSAutomated environmental monitoring & IoT cloud integration

Smart Energy Management System (EMS)

Automated energy management for AI Data Centers using the TCE IoT X200-16 Controller and TCE EMS Gateway. Real-time power monitoring, Cloud/DCIM integration, and alerts via LINE, Telegram, and Teams. Reduces energy costs and improves PUE.

Key Benefits

  • Reduce electricity costs by 15–25% through deep data analytics
  • Real-time measurement of kWh, kW, kVAR, and Power Factor
  • Alerts via LINE, Telegram, and Microsoft Teams
  • Cloud and DCIM integration via Modbus/MQTT/REST API
  • Sub-metering by department or machine
  • 4G LTE support for remote site deployments
Request an EMS Quote

Technical Specifications

Controller
TCE IoT X200-16
IoT Gateway
TCE EMS Gateway (TCE-EMS-GW)
Input/Output
16 DI, 8 DO, 4 AI, 2 AO
Communication
Modbus TCP/RTU, MQTT, HTTP REST API
Notifications
LINE, Telegram, Microsoft Teams
Connectivity
Ethernet, 4G LTE, DIN Rail

Our Service Process

We Support You Every Step of the Way

01

Needs Assessment

Our engineers conduct an on-site survey and assess your system requirements.

02

Solution Design

We design a system tailored to your organization and prepare a detailed quotation.

03

Installation & Testing

Our certified technicians install and commission the system to full operational readiness.

04

Training & Handover

We train your team on system operation and provide complete documentation.

05

After-Sales Support

Ongoing maintenance and 24-hour technical support for the lifetime of your system.

FAQ

DCIM · BMS · EMS — Common Questions

What is DCIM software and why does my data center need it?
DCIM (Data Center Infrastructure Management) software monitors and manages all physical infrastructure in real-time — power (PUE), cooling, temperature, humidity, and IT assets. It helps reduce energy costs, prevent downtime, and optimize capacity for AI Workloads.
What is the DFUN PBMS9000+61 Battery Monitor?
The DFUN PBMS9000+61 is an online BMS Battery Monitor for Lead Acid and Ni-Cad batteries in UPS and AI Data Centers. It continuously measures voltage, current, temperature, and State of Health (SOH) for up to 256 cells via Modbus TCP/IP and RS485. It detects failing batteries before they cause outages, extending battery life and protecting your AI Data Center.
What is the TCE EMS Gateway and how does it integrate with my systems?
The TCE EMS Gateway (SKU: TCE-EMS-GW) is an IoT Gateway that connects UPS, PLC, and Energy Meters to Cloud and DCIM platforms via Modbus, MQTT, and REST API. It supports Ethernet and 4G LTE connectivity, and sends alerts via LINE, Telegram, and Microsoft Teams. DIN Rail mount for easy installation.
Does ThaiConnect provide installation and after-sales support in Thailand?
Yes. ThaiConnect provides end-to-end service: consultation, system design, installation, commissioning, and 24-hour after-sales support for DCIM, BMS (DFUN PBMS9000+61), EMS (TCE IoT X200-16 + TCE EMS Gateway), and Busway systems across all of Thailand.

Ready to Optimize Your Data Center Infrastructure?

Consult our certified engineers at no cost. Contact us today for a proposal tailored to your organization's DCIM, BMS, or EMS requirements.